Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 11307118C


Addresses:

3105 N CAMPBELL AV


Inspection Status: Partial Pass

Inspection History: For trash and recycling enclosures

Permit Number - TD-DEV-0425-00116

Inspection Description - For trash and recycling enclosures

Inspection Status - Partial Pass

Date Description Inspector Results Comments
11/07/2025 For trash and recycling enclosures Partial Pass 11/7/25
Footers for 2 single attached Refuse Enclosures. Send pictures of loose material removed and all rebar 3" clear of dirt prior to concrete placement. Footer dimensions correct. Two bars at wall ends and three in the corners. #4 rebar reinforcing correct. Verts at 24" for stack bond. Request pre-grout inspection when ready with 1st lift built or at 6 ft with bond beam and weep holes. Use correct horizontal reinforcement.
11/13/2025 For trash and recycling enclosures Partial Pass 11/13/25
RE walls built to 6' with bond beam. Okay to pour grout. Fill all cells w/ verts and cover bond beam w/ 2" grout. Send picture of grout inspection weep holes. Request inspection when bollard footers and or mat for floor ready. Submit compaction report to the portal.
11/24/2025 For trash and recycling enclosures Partial Pass Okay to pour both refuse enclosure slab and approach.