Inspection Status: Partial Pass
Inspection History: ENGR Paving
| Date |
Description |
Inspector |
Results |
Comments |
| 03/17/2026 |
ENGR Paving |
|
Partial Pass |
3/17/26 Subgrade density complies. ABC density complies. Slopes and drainage in 4" AB is correct. Curb reveals good and tack coat on curbs. Okay to pave 2" AC mix #2. |
| 04/07/2026 |
ENGR Paving |
|
Passed |
|