Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Passed

Inspection History

Date Description Inspector Results Comments
02/02/2026 Passed 2/3/26
Gravel filled wattles are made and placed per plan and detail in The Erosion Control Plan. The wattles every other row perpendicular to the slope per plan.
Schedule inspection when hydroseeding all disturbed areas is complete.
10/31/2025 Partial Pass Overex of erosion repair beginning. call in weekly inspections to monitor progress.
11/10/2025 Partial Pass Proceed with check dam installation.
12/01/2025 Not Ready 12/1/25
Channel erosion repair check dams are not continuous end to end. Remove dirt and fill with rock. Request same inspection when ready
12/09/2025 Partial Pass 12/9/25 South Slope Channel Erosion Repair and Check dams built to Engineers’s RFI specifications and plan. Filter Fabric used in check dams in addition to the Riprap filler in between. Secondary rills at the bottom of slope also repaired correct.
Gravel Wattles will be placed when practical during array install.