Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Not Ready

Inspection History

Date Description Inspector Results Comments
07/09/2026 Not Ready One of the handicapped parking spaces needs to have the van accessible sign removed. It is the second stall closest to the entryway on the building side of the parking lot. It does not comply. There is enough van accessible spaces on site without it. ADA signage at these parking spaces on the building side need to follow D/2 on page 3 on the DP. The changes in the striping line thickness of access aisles and color of logo per detail the D/2 should be fixed or noted by Engineer in the As-Builts.
Move the wheel stops that are in the handicap parking spaces on the building side of the parking lot to 2.5' from front face of wheels stop to front face of curb per the detail B/2 on page 3. The other wheel stops at the EV chargers and bollards can remain in place.