Inspection Status: Not Ready
Inspection History: COT - RSPL - Plumbing Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/27/2026 | COT - RSPL - Plumbing Final | Not Ready | ||
| 02/11/2026 | COT - RSPL - Plumbing Final | Re-inspection required | 2/11/2026 Outdoor light at entrance not operating, furnace missing, refrigerator in living room, air registers are covered. Hot water heater outside verified not in scope of work: not connected, flue cap broken, gas line missing drip leg, T&P valve not piped. Dead front at main service panel needs labeled complete, knockouts need plugged at bottom. Missing smoke detector in bedroom and hall, missing outlets in bedroom & living room, outside receptacles need to be outdoor rated, and arc fault breakers needed in habitable areas. |
|
| 02/24/2026 | COT - RSPL - Plumbing Final | Not Ready | ||
| 04/30/2026 | COT - RSPL - Plumbing Final | Passed |