Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-1125-05664

Parcel: 141163640


Addresses:

7701 S FALSTER AV

Inspection Status: Re-inspection required

Inspection History: RSPL - Plumbing Progress

Date Description Inspector Results Comments
11/26/2025 RSPL - Plumbing Progress Re-inspection required 11-26-25: 18" of copper is required at main water and at water heater before transitioning to pex, add R3 insulation/wrap using 10 mil tape to hot leg of water heater & at main together with vacuum breakers and at each hose-bib, install hammer arrestor on dishwasher line, and add firefoam at all penetrations at top plates. Reschedule inspection when ready.
12/15/2025 RSPL - Plumbing Progress Passed 12/15/2025
Passed final on 12/01/2025, approved per AC.