Permit: TC-RES-1124-06645

Parcel: 120080170


Addresses:

4533 S 7TH AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
03/03/2026 COT - RSBU - Roof NailingĀ  Re-inspection required 3-3-26: add anchor bolts to marked locations, add nails to exterior sheathing at marked areas, missing A35 to gable end bracing-see details for information, add shot pins to interior sill plates at marked locations, replace floating 2x stud at marked area and add nails to roof sheathing at marked locations.
03/04/2026 COT - RSBU - Roof NailingĀ  Passed 03/04/2026
Corrections made to prior inspection.