Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof NailingĀ
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2026 | COT - RSBU - Roof NailingĀ | Re-inspection required | 3-3-26: add anchor bolts to marked locations, add nails to exterior sheathing at marked areas, missing A35 to gable end bracing-see details for information, add shot pins to interior sill plates at marked locations, replace floating 2x stud at marked area and add nails to roof sheathing at marked locations. | |
| 03/04/2026 | COT - RSBU - Roof NailingĀ | Passed | 03/04/2026 Corrections made to prior inspection. |