Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
06/23/2026 COT - RSEL - Electrical Final  Re-inspection required 06/23/2026
Receptacle under sink and laundry room need GFCI. Plug knockout under service panel. All habitable, hallway, and living room circuits require AFCI breakers.
07/08/2026 COT - RSEL - Electrical Final  Re-inspection required 07/08/2026
AC breaker over-amped at 40A, label calls for 30A. And AFCI on living room breaker.
07/10/2026 COT - RSEL - Electrical Final  Passed 07/10/2026
Corrections made.