Permit: TC-RES-1123-09203

Parcel: 14017295A


Addresses:

4929 S CHERRY AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
01/29/2024 COT - RSBU - Roof NailingĀ  Re-inspection required 1/29/24: new 2x4 wall at bedroom needs to be properly fastened to slab, existing 2x8 rafters to remain missing H2.5 clips, missing double 2x8 below RTU, H2.5 missing at new 2x8 rafters, existing 2x6 roof rafters missing H2.5 at bearing points, missing H2.5 at new 2x6 rafters, braced wall on east wall not complete missing anchors bolts at bottom plate and 2x4 not properly fastened to sheathing or bottom plate, braced wall nail schedule is not per plan, new braced wall panels missing per plan.
01/31/2024 COT - RSBU - Roof NailingĀ  Passed 1/29/24: new 2x4 wall at bedroom needs to be properly fastened to slab, existing 2x8 rafters to remain missing H2.5 clips, missing double 2x8 below RTU, H2.5 missing at new 2x8 rafters, existing 2x6 roof rafters missing H2.5 at bearing points, missing H2.5 at new 2x6 rafters, braced wall on east wall not complete missing anchors bolts at bottom plate and 2x4 not properly fastened to sheathing or bottom plate, braced wall nail schedule is not per plan, new braced wall panels missing per plan.
1/31/24: corrections made