Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Plumbing Final
| Date |
Description |
Inspector |
Results |
Comments |
| 08/06/2024 |
COT - RSPL - Plumbing Final |
|
Re-inspection required |
8/6/24: water hammer arrester required at (dishwasher, refrigerator, washer), two circuits required at kitchen, receptacle spacing at kitchen countertop not meeting code requirements, Insulate and UV coat water lines, A.V.V needs to be properly installed, Arc-fault breakers missing throughout, grounding required at gas piping, no roof access, smoke detector not properly installed. |
| 08/12/2024 |
COT - RSPL - Plumbing Final |
|
Passed |
|