Permit: TC-RES-1026-06065

Parcel: 136030230


Addresses:

8551 E 23RD ST

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
11/16/2026 COT - RSBU - Roof NailingĀ  Re-inspection required 11/16/2026
Roof covered over prior to inspection. Provide verifiable evidence, such as detailed images or receipts, of full scope of work completed according to approved plan. Detailed images of roof decking for nail or fastener schedule suffices. The last rafter on the fascia shows evidence of rot, please provide evidence or open up part of rafter system covered over to ensure it is structurally sound.