Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-1023-08985

Parcel: 140232690


Addresses:

5925 S EUCLID AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Stem Wall/Retaining Wall 

Date Description Inspector Results Comments
03/10/2025 COT - RSBU - Stem Wall/Retaining Wall  Re-inspection required 3/10/25: reinforcement at stem wall not Ready, Overlap at vertical reinforcement will not be met at first lift. Engineer will need to discuss possible solutions and revision is required.
04/17/2025 COT - RSBU - Stem Wall/Retaining Wall  Partial Pass 4/17/25
Partial pass, please request next inspection at 4' lift.
07/03/2025 COT - RSBU - Stem Wall/Retaining Wall  Partial Pass 7/3/2025 1st lift approved. All around. Okay to grout progress areas
07/08/2026 COT - RSBU - Stem Wall/Retaining Wall  Passed 07/08/2026
Final lift at CMU walls, verified added second #4 rebar at top bond beam. Okay to grout.