Inspection History Details
Inspection Status: Re-inspection required
Inspection History: BULD - Electrical Clearance
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/25/2025 | BULD - Electrical Clearance | Re-inspection required | 4/25/25 Called and left voicemail, no answer. |
|
| 05/01/2025 | BULD - Electrical Clearance | Re-inspection required | 05/01/25 Called and left voicemail, no answer. |
|
| 05/09/2025 | BULD - Electrical Clearance | Re-inspection required | 05/09/25 1. Bond bushings required throughout; 2. photovoltaic labels needed on conduit rooftop; 3. LABEL Needed at main service panel, DEPICTING A BUILDING WITH A ROOF THAT READS "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN", AS WELL AS, "TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY" PER 2017 NEC 690.56(C)(1)(A) |
|
| 06/23/2025 | BULD - Electrical Clearance | Passed | Approved all items addressed, DGC Clearance to TEP is required (separate service panel upgrades is required) |