Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 04/26/2024 |
COT - RSME - Mechanical Final |
|
Re-inspection required |
4/26/24: hammer arrestors needed at laundry room and dish washer. GFCI protected receptacle needed at laundry room. Exterior receptacle by front door not working. Arc fault protected breakers needed at all living spaces. T and p line needed to be cut 6 inches from final grade. Condenser unit for mini splits needs to be securely fastened to pad or ground. |
| 05/02/2024 |
COT - RSME - Mechanical Final |
|
Passed |
|