Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
11/16/2026 COT - RSBU - Roof NailingĀ  Re-inspection required 11/16/2026
Add shot pin at marker interior walls as marked. Side patio calls for joist hanger instead of A34 clips. Front patio gable end diagonal bracing needs A34 clip. Provide ladder to verify crickets and parapet wall. Provide truss calcs to verify bracing and layout.
11/17/2026 COT - RSBU - Roof NailingĀ  Passed 11/17/2026
All corrections made. Okay to proceed.