Permit: TC-RES-0625-03290

Parcel: 11709054A


Addresses:

1016 S RUBIO AV

Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
04/28/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Receptacles that exceed the box fill has to be replaced with bigger box to meet the cubic inches. Provide ko seals, grommets, and ground screws at all metal boxes. Provide proper cable to run in cavity and soon to be covered with plaster. Properly secure cables through once installed. Provide 1 1/4” cavity to protect it from physical damage. Per section 334.12 (B) #2 nm cable is not allowed per installation requirements. 4/28/2026
04/29/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed