Permit: TC-RES-0525-02573

Parcel: 133551150


Addresses:

9580 E MAGDALENA RD

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
08/12/2025 COT - RSBU - Roof NailingĀ  Re-inspection required Shot pins and anchor bolt at marked areas, check edge spacing on sheathing at roof and walls, should be 6"oc, over penetration at wall sheathing throughout
08/14/2025 COT - RSBU - Roof NailingĀ  Passed See previous notes, h25 clips at sil plate not nailed properly/missing nails, sil plate at marked area west wall needed anchor bolt, not shot pin