Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Preslab
| Date |
Description |
Inspector |
Results |
Comments |
| 07/08/2024 |
COT - RSBU - Preslab |
|
Re-inspection required |
No rebar reinforcement is in concrete footing or slab, subsoil has too many large rocks and pieces of concrete, existing concrete slab needs to have holes or key ways to keep new slab from moving on top of old slab. Subsoil needs to be compacted. |
| 07/10/2024 |
COT - RSBU - Preslab |
|
Passed |
7/10/24: Rebar reinforcement has been installed in footing and is properly supported off of ground. Existing slab has been drilled and rebar secured into holes. Okay to proceed with concrete pour. |