Permit: TC-RES-0426-01955

Parcel: 133477710

Inspection Status: Partial Pass

Inspection History: Pool/Spa - Plumbing

Date Description Inspector Results Comments
05/27/2026 Pool/Spa - Plumbing Partial Pass Why is there a gas line in the trench?
05/29/2026 Pool/Spa - Plumbing Re-inspection required 5/29/26
1. Gas line, pool, water and electrical conduit are all in the same trench. Gas line appears to be for a barbecue and has been valved off . Scotch guard has been scraped off the gas line due to the trenching. If gas line is abandoned then it will need to be removed from the gas meter and vented and capped off properly. furthermore if gas line is still active, it will need to be separated from electrical conduit by 12 inches horizontally.
06/23/2026 Pool/Spa - Plumbing Re-inspection required previous issue not addressed, will need proof of correction or have trench re dug. checked all alarm and safety devices, grounding, and electrical, all are correct
06/26/2026 Pool/Spa - Plumbing Canceled
06/30/2026 Pool/Spa - Plumbing Passed Correction made