Permit: TC-RES-0326-01533

Parcel: 11707052B


Addresses:

505 S 6TH AV

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
04/22/2026 COT - RSPL - Plumbing Final  Re-inspection required new flooring being installed at time of inspection. cannot get to all fixtures and plumbing lines to conduct inspection. 4/22/2026
04/24/2026 COT - RSPL - Plumbing Final  Re-inspection required all water lines that are not within the thermal envelope requires insulation. hot water line that runs parallel to cold line requires insulation. access to crawl space is required. provide hammer arrestors where quick closing valves are installed. 4/24/2026
04/30/2026 COT - RSPL - Plumbing Final  Passed All corrections were made. 4/30/2026