Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Underground
| Date |
Description |
Inspector |
Results |
Comments |
| 04/09/2024 |
COT - RSEL - Electrical Underground |
|
Re-inspection required |
4/9/24: Arc-fault breakers missing at multiple locations in sub-panel, WR receptacles required on exterior, mini split refrigerant lines need to be properly supported and UV coated, Electrical at mini split needs to be properly supported. mini split and water heater need disconnect boxes, T&P needs to be installed at Water heater, GFCI required at bathroom, hose bib needs vacuum breaker and proper insulation and UV coat, licensed (plumber,electrician and HVAC) will need to provide letters stating that all work done in casita meets or exceeds 2018 IRC prior to final. |
| 09/30/2024 |
COT - RSEL - Electrical Underground |
|
Passed |
|