Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Passed
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 04/09/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
4/9/24: Arc-fault breakers missing at multiple locations in sub-panel, WR receptacles required on exterior, mini split refrigerant lines need to be properly supported and UV coated, Electrical at mini split needs to be properly supported. mini split and water heater need disconnect boxes, T&P needs to be installed at Water heater, GFCI required at bathroom, hose bib needs vacuum breaker and proper insulation and UV coat, licensed (plumber,electrician and HVAC) will need to provide letters stating that all work done in casita meets or exceeds 2018 IRC prior to final. |