Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 7-14-25: Add anchor bolts 23" throughout-see details A-301#3&1. Add shot pins to marked areas-shot pins re required 6" from the end of an interior plate, several loose roof panels-add nails t marked locations, and a CS16 straps on interior posts to beam with 8 nails above and below connecting points.Submit a revision for all perimeter framing gaps along existing masonry walls, add nails to exterior sheathing at entry way where nails along edges/joints are closer than 3/8" and where overpenetrated more than 1/16". | |