Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof NailingĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 07/14/2025 |
COT - RSBU - Roof NailingĀ |
|
Re-inspection required |
7-14-25: Add anchor bolts 23" throughout-see details A-301#3&1. Add shot pins to marked areas-shot pins re required 6" from the end of an interior plate, several loose roof panels-add nails t marked locations, and a CS16 straps on interior posts to beam with 8 nails above and below connecting points.Submit a revision for all perimeter framing gaps along existing masonry walls, add nails to exterior sheathing at entry way where nails along edges/joints are closer than 3/8" and where overpenetrated more than 1/16". |
| 07/21/2025 |
COT - RSBU - Roof NailingĀ |
|
Passed |
7-21-25: okay to dry-in roof. |