Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
06/04/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6/4/25: Fastners shall penetrate no more than 1/8" and shall be no closer than 3/8" from edge of sheathing. Spacing at sheathing not per plan at north west corner of home (marked in red), shot pins required 6" from edge of sill plate, truss clacs must be provided at time of inspection, 2x4 at nailer truss must be spaced 24" o.c,
06/06/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Approved. All items have been completed. 6/6/2025