Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
10/09/2025 RSBU - Building Final  Re-inspection required 10-9-25: cut cleanouts to grade, weather resistant receptacles are required on exterior, seal water closets, arch fault breakers are required for all habitable areas to include, bedroom, living room, kitchen, hallway, using a permanent marker, write" non metallic plumbing " inside of panel, add R3 insulation to hose bibs and hot water leg of water heater & complete grounding at water heater. An enclosure protecting the water heater from the elements is required, install metallic address label on panel, install an address identification near front door identifying unit, complete all plumbing and install kitchen and bathroom fixtures, missing water bonding-see plans for details, seal around the exterior light fixture to where no electrical wirings are accessible.
10/30/2025 RSBU - Building Final  Passed 10/30/25 corrections made