Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
06/04/2025 COT - RSBU - Roof NailingĀ  Re-inspection required 6/4/25: Fastners shall penetrate no more than 1/8" and shall be no closer than 3/8" from edge of sheathing. Spacing at sheathing not per plan at north west corner of home (marked in red), shot pins required 6" from edge of sill plate, truss clacs must be provided at time of inspection, 2x4 at nailer truss must be spaced 24" o.c,
06/06/2025 COT - RSBU - Roof NailingĀ  Passed Approved. All items have been completed. 6/6/2025