Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 04/18/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Loose shear panels. Proved titan bolts at all that are out of the center third of the bottom plates. Add cut nails to interior walls along with fire blocking at 8´. |
| 04/22/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
4/22/24: Loose shear panels have been properly nailed off, bolts have been drilled into plate and floor on bottom plate, cut nails have been added to bottom plate on interior walls and fire blocking is installed at 8' height in all walls. |