Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 9.2.2025 Missing 6” screws on floor trusses in first floor per truss calcs, missing A35 clips on detail SD2-14, missing H2.5 or mechanical connection clips on second floor at JG1 & JG2 trusses (see red markings), nail loose sheathing per red markings on second floor and bottoms plates. |
|
| 09/05/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 9.52025 Corrections made from prior inspection, verified with letter that mechanical connection on roof girder truss at JG1 to B1G is correct with heel and nails. |