Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/21/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Framing at master bedroom windows not per plan, renail exterior shear wall on east side, install anchor bolt within 12" of all Hold-downs, missing king stud in opening of shower window and bedroom 3 window, remove all temporary blocking on truss bottom cords, install A34 clips at ladder blocking over slider per plan
03/27/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed