Permit: TC-MDP-1124-01340

Parcel: 137042050


Addresses:

5401 S IDA LN

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
10/22/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10-22-25: SW2 at garage & on other side of staircase calls for anchor bolts 32" o.c. Or Ramset pins at 8" o.c., missing sheathing at shear walls, missing fire blocking at staircase, add a shot pin within 6" at the ends of sill plate, add angle clips to every other stud at upstairs firewall, add nails and 2x4 to damaged sill plate to decking at upstairs southeast bedroom, missing A-35's and at each end of garage and at garage shear wall at 16" o.c., add nails at edge underneath front porch, missing A-34’s at each end of gable end bracing.
11/03/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Canceled 11-3-25: canceled by contractor.
11/05/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 11-5-25: corrections made-exterior clips/sheathing and framing approved.