Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
06/17/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Electrical lines exceeding the cubic inches in pancake box right of garage. Add nail plates to electrical lines right of garage entry along with other marked areas in red. Add blocking to pex lines being to close to light housing. Missing smoke detector outside of bedroom 1st floor. Missing pancake box for light/fan in bedroom 1st floor. Remove all electrical wires from gusset plates. Secure ABS midway. Lower t-stat at 48”. Secure looped romex throughout. Secure orange tubing in place. Jacket for 6 awg has been damaged near pantry. Secure line sets midway. Seal all exterior penetrations. Missing receptacle at double lav second floor bathroom hall. Secure fresh air intake. Add blocking at 4gang boxes. Add fire blocking underneath laundry tray. Lath is incomplete. 6/17/2025
06/20/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 6/20/25 corrections made