Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Progress

Date Description Inspector Results Comments
07/16/2025 RSBU - Building Progress Re-inspection required 7-16-25: add firefoam to penetration above tub, seal vapor barrier at garage, master bedroom, great room in several areas & bedroom 4. Lower thermostats to 48" o.c., add strap to condensation line, all DWV must be under test, 12" clearance required between pex and can lights at bathroom 2-block using 2x4, osb, drywall,or relocate to allow for clearance requirements.Secure/staple EV charger and add a bank plate at marked location hallway from garage.
07/17/2025 RSBU - Building Progress Passed Passed 7/17/25