Permit: TC-MDP-1123-01777

Parcel: 140443340


Addresses:

6148 E CAMPOLINA TR

Inspection Status: Partial Pass

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
10/14/2025 COT - RSBU - Roof Nailing  Partial Pass 1. Missing truss layout, plan D.
2. Cracked truss in garage see markings on stud.'
3. Cracked truss bottom chord in kitchen, marked on the slab in red.
4. Cracked truss in kitchen just before island. Marked in red.
10/16/2025 COT - RSBU - Roof Nailing  Partial Pass may dry in do not load until truss fixes
10/20/2025 COT - RSBU - Roof Nailing  Passed 10.20.2025
Corrections made to damaged trusses and engineer letter provided.