Permit: TC-MDP-1025-00691

Parcel: 140444880


Addresses:

5963 E BENBURB LN

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
02/27/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 02/27/2026
Rear patio calls for post strap connection per detail SD-602, add anchor bolt at marked locations, missing 2ft shear wall on east side of garage near front, missing H2.5 or 6" strong drive structural screw on front porch midway on very truss to top plate per detail SD-462.1, add (2) HTC4 8’ OC on interior non bearing wall upstairs.
03/06/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 03/06/2026
Corrections made to 2/27/26 inspection.