Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/27/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 02/27/2026 Rear patio calls for post strap connection per detail SD-602, add anchor bolt at marked locations, missing 2ft shear wall on east side of garage near front, missing H2.5 or 6" strong drive structural screw on front porch midway on very truss to top plate per detail SD-462.1, add (2) HTC4 8’ OC on interior non bearing wall upstairs. |
|
| 03/06/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 03/06/2026 Corrections made to 2/27/26 inspection. |