Permit: TC-MDP-1025-00624

Parcel: 140280940

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
05/06/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 5-6-26: add nails per schedule at SW11-4" o.c. at edges/joints and 12" o.c. In the field, add 4' gable end bracing at great room & at bedroom 3-see detail 301, add 3" x 3" washers at all shear walls, add backing/blocking 9" above rim of tub, add a cs20 strap at back patio post to beam, add rsp4's to marked locations, add anchor bolts along exterior walls where unable to add a minimum of 7 nails at masa clips.
05/07/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed corrections made