Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-1025-00611

Parcel: 140281220

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
07/10/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 07/10/2026
Add nails to loose roof panels in bedroom area near garage. Add anchor bolts as marked. Add missing HTT5 at rear SW11 and add steel washer plates to anchor bolt. Rear patio ledger missing (2) nails 24 o.c. Add (2) H2.5 clips to A6G girder on middle bearing to top plate.
07/14/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 07/14/2026
Corrections made.