Permit: TC-MDP-1025-00611

Parcel: 140281220

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
07/10/2026 COT - RSBU - Roof NailingĀ  Re-inspection required 07/10/2026
Add nails to loose roof panels in bedroom area near garage. Add anchor bolts as marked. Add missing HTT5 at rear SW11 and add steel washer plates to anchor bolt. Rear patio ledger missing (2) nails 24 o.c. Add (2) H2.5 clips to A6G girder on middle bearing to top plate.
07/14/2026 COT - RSBU - Roof NailingĀ  Passed 07/14/2026
Corrections made.