Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/09/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 07/09/2026 Add one inch insulation to 3/4" hot PEX line inside conditioned space per IRC 2024 N1103.5.2 (R403.5.2), brace air registers throughout, add cleanout at tub in bath 2 per drain waste plan, add bushing to exhaust box for Romex wire at primary bathroom, secure 6AWG wire near AC line set. |
|
| 07/10/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 07/10/2026 Corrections made. |