Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/20/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 4-20-26: block register at kitchen, seal vapor barrier at south wall/west wall at several areas including corner located in master bedroom, fix tears to flex at marked locations, fire foam kitchen exhaust at Boca plate, seal vapor barrier at bedroom 4& 3 and seal all penetrations at top plates, all horizontal penetrations from an unconditioned space to a conditioned space at garage must be sealed. Stopped inspection-additional items may be noted. | |
| 04/21/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 04/21/2026 Corrections made to prior inspection, walked rest of house. Added fire foam at range hood and added insulation at water PEX line in garage. |