Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
09/18/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 9-18-25: add nails at all shear walls per schedule, add anchor bolts with 3x3" washers at marked locations to include: garage, interior load bearing walls and at shear walls, add H25's at garage bearings points -see SD3/1, missing 2 anchor bolts at 2x4 sill plate at stairs-see SD2/40, add nails sill to decking at marked locations and nails to A35's at marked locations.
09/22/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 9/22/25
1. Missing 2 anchor bolts at stairs sill.
09/23/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 9-23-25: exterior/interior clips approved.