Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 9-18-25: add nails at all shear walls per schedule, add anchor bolts with 3x3" washers at marked locations to include: garage, interior load bearing walls and at shear walls, add H25's at garage bearings points -see SD3/1, missing 2 anchor bolts at 2x4 sill plate at stairs-see SD2/40, add nails sill to decking at marked locations and nails to A35's at marked locations. | |
| 09/22/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 9/22/25 1. Missing 2 anchor bolts at stairs sill. |
|
| 09/23/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 9-23-25: exterior/interior clips approved. |