Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
06/16/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 6/16/25: UFER ground must be properly secured, nail plates required throughout where rough in is with 1 1/4" of face of 2x, bedroom 2 fan romex must stub into box 1/2", 4"x8" plate required at dryer vent exhaust, seal chase at dining room east half, can light in dinning room must have romex sheathing in box 1/2", DWV not under test, tear at mast bath vapor barrier must be sealed, refrigerant lines must be supported in wall, pex lines must be 12" away from can lights at master bathroom, pex lines in wall require support every 48" o.c, thermostat shall be no higher than 48" o.c, Smurf tube at garage not complete to metallic box,.
06/20/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed All corrections were made. 6/20/2025