Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
| Date |
Description |
Inspector |
Results |
Comments |
| 05/29/2025 |
COT - RSBU - Roof Nailing |
|
Re-inspection required |
5/29/25: Anchor bolts required with 12" of edge of sill plate, shear walls not fastened per schedule, fasteners shall be no closer than 3/8" from edge and shall penetrate no more than 1/8", incorrect hangers used at truss EJ41 (plans call for LSU24), Anchor bolts required at front porch columns and back porch columns, Gabel end bracing required at back porch framing, gabel end bracing missing throughout, Gabel end bracing spacing at garage not per plans, H2.5 required at truss A41B (2). STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
| 06/02/2025 |
COT - RSBU - Roof Nailing |
|
Re-inspection required |
6-2-25: no plans on site. Arrived on site at approximately 6:50, contacted contractor at 7:04 and left at 7:23 |
| 06/03/2025 |
COT - RSBU - Roof Nailing |
|
Passed |
6-3-25: roof nailing approved. |