Permit: TC-MDP-1023-01689

Parcel: 140443420


Addresses:

6180 E CAMPOLINA TR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10.7.25
Shot pins missing throughout
Fastener spacing incorrect at Tply throughout
Fasteners over penetrate AND improperly penetrate Tply throughout
Clips missing at perpendicular walls on 2nd floor per plan
Anchor,bolt missing at cut plate at uffer
LU hangers missing at glulam over kitchen area
10/09/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 10.9.25
Corrections made