Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 10.27.2025 Front porch base of column needs concrete fix, nuts of HTT4 interior shear walls not secured, add anchors bolts at marked locations, ledger at front porch calls for 2x8 ledger, per detail SD5-49 floor truss needs solid filler, A05 and A02M truss missing brace. |
|
| 10/28/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10.28.2025 Corrections made to prior inspection and bracing on trusses verified. |