Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Canceled | ||
| 10/27/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 10.27.2025 Add anchors bolts as marked and add staples as marked to shear walls throughout. |
|
| 10/28/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 10.28.2025 Partial pending shear wall staple over-penetration and staples within 3/8" of the edge. Add anchor bolts as marked. Verify at intermediates. |
|
| 10/29/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10.29.2025 Corrections made to prior inspection. |