Permit: TC-MDP-0925-00524

Parcel: 141156850

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
08/07/2026 COT - RSPL - Plumbing Final  Re-inspection required 08/07/2026
Garage entry door needs to be self-closing, receptacle under island sink needs to be secured, add water hammer arrester to dish washer, missing large areas of insulation in attic, missing refrigerant caps at air condenser, add post-tension tag to hose bibb. Conditions paperwork needs to satisfied prior to building final.
08/13/2026 COT - RSPL - Plumbing Final  Re-inspection required 8-13-26 Bedroom 2 smoke detector shall be a minimum of 4" away from wall needs to comply with NFPA 72*missing post tension tag at hose bib* primary bathroom countertop switch closest to mirror left of entry door furthest from door on plan shows as optional seeing that it wasn't used for that option. It should be blanked.* all thermostats are required to be at 48 inches if controls are at bottom then 48 inches to bottom is OK * please provide tall enough ladder for attic access.
08/17/2026 COT - RSPL - Plumbing Final  Passed 8-17-26: plumbing final approved.