Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/15/2026 | COT - RSME - Mechanical Final | Re-inspection required | 7-15-26 *doorbell appears to have no power * anti tip required at range, range is not installed. *Master bath left of sink counter top receptacle needs to be properly installed w/plate. * no running water at master bath sink. * Remove paint off of 20 minute rated tag at garage door. * Threshold at garage door must meet ADA requirements. * half hot receptacle in Northwest bedroom temper resistance compromised. * North bedroom at ceiling possible leak will need to repair. * properly terminate 90° fitting at PRV. * post tension tag required at hose bib. * lockout caps at refrigerant line located on floor AC unit must be properly installed. * address tag required at main panel. * attic, not walked due to needing a 10 foot ladder or better. | |
| 07/28/2026 | COT - RSME - Mechanical Final | Not Ready | 07/28/2026 Not all corrections made. Garage door needs to be self-closing, door bell not functioning, missing address tag at service panel. Conditions paperwork needs to be satisfied. |
|
| 07/29/2026 | COT - RSME - Mechanical Final | Not Ready | Threshold at garage needs to meet ADA. Refrigerant caps still not installed. 7/29/2026 | |
| 07/30/2026 | COT - RSME - Mechanical Final | Passed | Approved corrections were made. 7/30/2026 |