Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0924-01130

Parcel: 140442740


Addresses:

6147 E CAMPOLINA TR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/20/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 3/20/2026
Add anchor bolts at marked locations, add h2.5 clips at interior bearing wall to truss A4B thru A8G at double top plate.
03/20/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 3/20/2026
Add anchor bolts at marked locations, add staples at shear walls as marked where over-penetration occurs. Verified fix to sill plate near electrical service panel.
03/23/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 3.23.26
Corrections implemented, approved to proceed