Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
05/05/2025 COT - RSPL - Plumbing Final  Re-inspection required 5/5/25: clean out at driveway missing. SWG meter not installed, Non metallic piping label required at main panel, label for future solar equipment required at main panel, 3” clearance for grade at A/C condenser required, A/C disconnect box most be properly secured and all unused knockouts must be sealed, post tension tag required at hose bib, gate required at CMU wall, thermostat shall be no higher than 48” above finish floor, Garage receptacles must be GFCI, no attic access.STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
05/09/2025 COT - RSPL - Plumbing Final  Passed 5/9/2025 approved.